STAAD.Pro Help

D1.B.2.4 General Format

The command syntax in the STAAD input file for assigning castellated beams is:

Section Sizes

The table for non-composite castellated profiles is available in the legacy database format only.

MEMBER PROPERTY AMERICAN
member-list TABLE ST section-name

All castellated beams are listed with their nominal depth and their nominal weight per foot (i.e., similar to the nomenclature used for American wide flange shapes).

Tip: You can click View Table in the Section Profile Tables dialog to view the properties table, which includes the root beam profile size used for each castellated beam.

Example

MEMBER PROPERTY AMERICAN
10 TO 20 TA ST CB15X33
2 TABLE ST CB12X28

Assigning Design parameters

Under the PARAMETERS block on input, the code name must be specified as:

CODE AISC CASTELLATED

Example

PARAMETER
CODE AISC CASTELLATED
UNL 0.01 MEMB 25 31
FYLD 50 MEMB 25 31
SOPEN 11.124 MEMB 25 31
…
CHECK CODE MEMB 25 31